ThinPrep® 2000
Processor (TP 2000)
The
ThinPrep 2000 Processor (TP 2000) is an automated slide
preparation unit used with the ThinPrep Pap Test for
cervical cancer screening. The TP 2000 can also be
used for non-gynecological specimens such as for the
diagnosis of cancers of the lung, bladder, and gastrointestinal
tract, and in the preparation of fine needle aspiration
of thyroid and breast.
The TP 2000 utilizes Controlled Membrane TransferTM technology
(CMT). CMT is a computerized process and patented membrane
technology that controls dispersion, collection and
transfer of diagnostic cells from the sample to the
slide. This ensures that the slide is representative
of the original sample collected in the vial.1
At the laboratory, the sample vial is placed into the TP 2000. Under the
control of the instrument's microprocessor, the following steps are
automatically performed: First, a gentle dispersion step breaks up
blood, mucus, non-diagnostic
debris, and then thoroughly mixes the sample. A series of negative
pressure pulses are generated which draw fluid though a ThinPrep
Filter to collect
a thin, even layer of diagnostic cellular material. The TP 2000 constantly
monitors the rate of flow through the ThinPrep Filter during this
process to collect an appropriate amount of material. The cellular
material is
then transferred to a glass slide using computer controlled mechanical
positioning and positive air pressure. The slide is then ejected
into a cell fixative bath, ready for staining, coverslipping and
evaluation.
This highly precise process is controlled by a microprocessor based system developed by Cytyc software, electrical and mechanical engineers, which allows real-time process control. The TP 2000 is a complex electro-mechanical instrument, which consists of four major components:
- The precision mechanism that is responsible for holding and moving the sample vial, the ThinPrep filter and the microscope slide through the complete process.
- A pneumatic system responsible for generating precisely controlled positive and negative pressures.
- Electronics which power the instrument and provide the means for the system microprocessor to control the various motors, valves and sensors in the mechanical and pneumatic systems.
- Software that runs on the microprocessor to orchestrate the entire slide preparation process. The operator simply loads a sample, slide and filter and pushes "Start"; the software takes over and signals when the slide is ready. The design of the TP 2000 allows field upgradeablity by sending software updates on PCMCIA cards. With the flexibility of a software based system, advances in technology can be quickly integrated into existing systems.
SPECIFICATIONS
Throughput:
Approximately 25 samples per hour. Up to 50,000 samples per year with a single 8-hour shift.
Dimensions:
18" wide x 15" deep x 19.5" high
46 cm x 38 cm x 50 cm
approximately 41 lb/18.6 kg
Power Requirements:
Voltage Autoranging between 100/120 and 220/240 VAC +/- 10%.
|